| Sector | abcRoads | Tender Value | INR 64.84 Lakhs approx. | Location | Orissa (Odisha) - India | Ref.No | 86738164 | Closing Date | 25 - Aug - 2025 | | | Shifting of Lt line from Jambubania village to Danra Village due to widening and strengthening of Talcher Gopalprasad Kaniha Road (to Hm) ,2.0 ,Shifting of LT line from Jamubahali Village to Danara Village due to widening and Strengthening of Talcher Gopalprasad Kaniha Road from 16.194 to 17.5 km. in Angul District.
Material For LT AB Cable Line
9 Mtr. long 300 Kg. PSC Pole ,LT Stay set Complete ,7/12 SWG GI stay wire, Grade -2 ,LT stay Clamp ( 1.40Kg/pair) ,LT Stay insulator ,Pole clamp for EYE hook for (XLPE Aerial bunched Cable) ,EYE hook for XLPE Aerial bunched Cable ,Dead End Clamp suitable for messenger XLPE Aerial bunched Cable ,Suspension Clamp with EYE hook for ABC ,4C×50 mm² (P)+1C×50 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable) ,Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm ,Insulated piercing connector.Type-B-main 25 to 150 sq.mm & Tap-6 to 35 sq.mm ,GI Pipe Earthing (each 5th pole to earth) ,Coil Earthing ,No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing ,Danger plate (LT) ,Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510) ,GI barbed wire anticlimbing device 3 Kg. Per support ,Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510) ,GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole) ,Black Paint(GIS Numbering & Zebra Stripping) ,Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background ,Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 124 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.) ,Concreting ratio 11.53(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole) ,Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth
resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)
around pipe . ,Dismantling of Materials
Dismantling of 9/8 Mtr. PCC/Joist Pole ,Dismantling of varous size of LT AB Cable ,Shifting of 11kv ,Lt line from Suluda College to Kumunda Village due to Widening and Strengthening of Talcher Gopalprasad Kaniha Road from 23.79 to 35.0 km. in Angul District
Material Of DP Without AB Switch
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)-DP
(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG) ,Top Channel(GI) 100X50X6mm, 9.56 KG/Mtr., each Channel(GI) length 2.3 mtr., 2 no's Channel(GI) required =( 2x9.56x2.3) ,Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280) ,Double Pole Belting Channel(GI) 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 1.66 Mtr., 4 no's Channel(GI) required =( 7.14x1.66x4) ,50x50x6mm.GI Bracing Angle(GI), 4.5Kg./mtr., each Angle(GI) length 2.671 mtr., 4 nos Angle(GI) required = (4.5x2.671x4) ,Danger Plate, 2 no's. ,Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510) ,H.T. Stay clamp, 50x8 mm. Flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair) ,H.T. Stay set (Complete ) ,H.T. Stay Insulator Type-C ,7/10 SWG Stay Wire 15kg /stay ,Gi Pipe Earthing 40mm. 3 Mtr. Long ,50x6mm Flat(GI) for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36 ,GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg) ,Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 8 no's = (8x0.59x0.510) ,11 KV pin insulator polymer ,H W fitting(B&S) 70KN, 3Bolt ,Disc insulator (B&S) 70 KN polymer ,Non-Metallic Ties-11KV 100Sqmm CVRD AAAC ,IPC for 100 sq.mm AAA conductor (For covered conductor)-11kV ,Spike (GI ) (using 50x6mm Flat(GI) welded with 8 mm square bar) ( 2 Nos of spike per Set in each Pole ) ,GI Nut , Bolt & Washer of different sizes (12.261 Kg each DP without AB Switch) ,Fixing of complete 11KV line Complete stay set includes
1) Turn Buckle Assembly
2) Stay Rod & Stay plate
3) Stay Insulator
4) Stay Wire.
5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 124 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard. ,Concreting ratio 11.53(M-20 Grade) (500mmX500mmX1800mm) = 0.45Cu.mtr(Per Pole) ,Couping ratio 11.53(M-20 Grade) with dimension (500X500X450)= 0.1125 Cu mtr(Per Pole) ,Provide necessary civil material for construction of Earthing chamber, excavation & installation of incuding earthingpipe dia up to 100mm dia for length of 3Mtr.Scope also includes necessary nut |
|
|